OPERATION & MAINTENANCE MANUAL SWE18UF
86
5.2.4 Fuel System
Parts
Qty.
Intervalhours
8
50
100
250
500
1000
2000
1. Vent sediments in fuel tank
1
2. Vent water and sediments in
water-oil separator
1
3. Change fuel oil filter
1
4. Change oil-water separator
1
5. Check fuel
hose
leakage and crack
crack and bend
Note】:” means that to check the fueling strainer every 100 hours and drain once, and change
every 1000 hours.
Recommended fuel:
Please use high quality diesel fuel (GB252 0# in normal condition; 10# for the winter) only, do not use
kerosene.
Fueling
1) Refer to “stop engine” chapter, park the excavator properly and turn off the engine correctly.
2) Check fuel indicator on monitor, do fueling work if necessary.
3) Prevent any dirt, dust, water or other impurity from getting into fuel tank or fuel system.
4) Make sure that there is no fuel sparked onto the ground in the fueling work every day after the work in
order to prevent coagulation of fuel.
5) Put on cap after fueling.
Be caution about the fuel. Turn
off engine before fueling. Do not
smoke while fueling the fuel tank
or work near the fuel system.