EasyManua.ls Logo

Supermicro X14SAE - Overheat (Oh);Fan Fail LED; Nic1;Nic2 (Lan1;Lan2) Led

Supermicro X14SAE
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Fail LED
Pin Definitions (JFP1)
Pin# Definition
5 +3.3 V
6 PWR Supply Fail
Overheat (OH)/Fan Fail LED
Connect an LED cable to pins 7 and 8 of the Front Control Panel to use the Overheat/Fan Fail
LED connections. The LED on pin 8 provides warnings of overheat or fan failure.
For a detailed diagram of the X14SAE/X14SAE-F motherboard, see the layout under "Quick
Reference" on page 13.
OH/Fan Fail Indicator
Status
Pin Definitions (JFP1)
State Definition
Off Normal
On Overheat
Flashing Fan Fail
OH/Fan Fail
Pin Definitions (JFP1)
Pin# Definition
7 +3.3 V
8
OH/FAN Fail
LED
NIC1/NIC2 (LAN1/LAN2) LED
The Network Interface Controller (NIC) LED connection for LAN port 1 is located on pins 11 and
12 of JFP1 on the X14SAE/X14SAE-F motherboard, and LAN port 2 is on pins 9 and 10. Attach
the NIC LED cables here to display network activity.
For a detailed diagram of the X14SAE/X14SAE-F motherboard, see the layout under "Quick
Reference" on page 13.
LAN1/LAN2 LED
Pin Definitions (JFP1)
Pin# Definition
9 +3.3 V Stby
10 NIC2 Link/Active LED
11 +3.3 V Stby
12 NIC1 Link/Active LED
60
X14SAE/X14SAE-F: Component Installation

Table of Contents

Related product manuals