Power Fail LED
Pin Definitions (JFP1)
Pin# Definition
5 +3.3 V
6 PWR Supply Fail
Overheat (OH)/Fan Fail LED
Connect an LED cable to pins 7 and 8 of the Front Control Panel to use the Overheat/Fan Fail
LED connections. The LED on pin 8 provides warnings of overheat or fan failure.
For a detailed diagram of the X14SAE/X14SAE-F motherboard, see the layout under "Quick
Reference" on page 13.
OH/Fan Fail Indicator
Status
Pin Definitions (JFP1)
State Definition
Off Normal
On Overheat
Flashing Fan Fail
OH/Fan Fail
Pin Definitions (JFP1)
Pin# Definition
7 +3.3 V
8
OH/FAN Fail
LED
NIC1/NIC2 (LAN1/LAN2) LED
The Network Interface Controller (NIC) LED connection for LAN port 1 is located on pins 11 and
12 of JFP1 on the X14SAE/X14SAE-F motherboard, and LAN port 2 is on pins 9 and 10. Attach
the NIC LED cables here to display network activity.
For a detailed diagram of the X14SAE/X14SAE-F motherboard, see the layout under "Quick
Reference" on page 13.
LAN1/LAN2 LED
Pin Definitions (JFP1)
Pin# Definition
9 +3.3 V Stby
10 NIC2 Link/Active LED
11 +3.3 V Stby
12 NIC1 Link/Active LED
60