POWER UNIT 6-4
Remove battery charge coil 1. (See page 4-4)
Disconnect CKP sensor connector and remove sensors
2.
Disconnect cylinder temperature sensor connector and remove
sensor
3.
Remove two bolts and rectifier & regulator.
Remove bolt and low pressure fuel filter bracket.
Disconnect water hose
4 from thermostat cover and engine
holder.
Disconnect exhaust manifold temperature sensor connector and
remove sensor
5.
Loosen screw and disconnect oil pressure switch lead wire
6.
Disconnect neutral switch lead connector wire
7.
Disconnect all engine wiring harness connectors from ECM,
then remove ECM
8.
Disconnect the PTT motor cable wire leads (G, Bl) from the
PTT relays.
Remove positive (+) battery cable from starter motor relay.
ECM