Pagina 7.41
7.15.1. POWERED MODELS
Figure 7.15-1
6.
Remove the secondary shaft assembly from
the belt and place it on a work bench.
7. Remove the spacer (d) and the pin (e) from
the flywheel assembly.
Figure 7.15-2
To disassemble the copper disk:
8. Back off the 6 screws (f)
hexagonal wrench.
CAUTION: Take particular care with
the copper disk, as it bends easily and
may then cause problems after
reassembly, by brushing against the
winding block.
CAUTION: During reassembly, lock
down the s
wrench setting of 6Nm.
To reassemble the secondary shaft assembly,
carry out the above steps in reverse order.
CAUTION: After completing the
reassembly, carry out the adjustment
procedure described in paragraphs: 8.1.
“Belt tension” and 8.4. “