Cardio WAVE EXCITE +: Service & maintenance manual - rev. 4.1
Pagina 9.16
9.3.3.3. Default Setting
To load the default parameter values, scroll using the +/- effort level keys until the display shows:
DEFAULT SETTING ?
Press ENTER. display shows:
CONFIRM ?
press ENTER to write the default values to the low kit, and return to the upper menu level by
pressing CLEAR for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.3.3.4. Table of configuration parameters:
Id
(Par.)
Units Name Description
LED
powered
Self-
powered
1
decimal
[Rt]
Transmission Ratio
3412
4248
2
[Rvel]
Speed ratio
400
400
3
mA
[Im]
Minimum braking
500
500
4
W
[Pmc]
Constant maximum power
200
200
5
in cent [Km2]
Power factor correction
(constant torque)
85
85
6
0.1N
[Ca]
User friction torque
10
10
7
°C
[Tea]
Maximum temperature on the coil
125
125
8
User
Rpm
[RPMmin]
Minimum user SPM
(start cut braking ramp)
35
35
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
250
400
10
User Rpm
[RpmF2]
Battery charge current
0
400
11
- FlagReg
Brake board Identification Code
See Note:
(*)
See Note:
(*)
12
0.1N [D_Ca]
User delta friction torque
30
30
13
-
-
Enable flag for registers at address ≥ 100
-
-