Cardio WAVE EXCITE +: Service & maintenance manual - rev. 4.1
Pagina 6.41
6.15.2. HAND SENSOR
HUMAN BODY “CONTINUITY”: it’s well known that for somebody it’s very difficult,
nearly impossible, to measure their HR using the hand sensors. This due to a lot of
possible causes which could fake the “quality” of the contact between the human skin
and the HS plates, as: hands only just washed or particularly dry, acidity of the skin
and/or a particular body fat mass index. For these people it’s suggested to wear the chest
belt transmitter.
HS CORRECT USE: Grasp both the upper and lower plate avoiding clenching them too
hardly. Avoid washing the hands using soaps that can dry the skin too much.
NO
Receiver Boar d
defective.
Repl ace.
THE TELEMETRIC HR
SIGNAL IS INCORRECT
(Hand Sensor)
Set the pri ori ty on the
Hand Sensor .
Probl em sol ved?
Check the state of
wear of Hand Sensor cabl e.
Probl em solved?
OK
OK
NO
2
OK
NO
YES
Check the Display SW
versione and the g r ounding of
the Receiver Boar d.
3
YES
YES
1
NO