TRAÇABILITÉ CRÉATIVE
CREATIVE TRACEABILITY
TECHNOMARK
1 Allée du développement 82
42350 La Talaudière (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : info@technomark-marking.com
V : SJ Le : 20/06/17 R : DD
www.technomark-marking.com
Maximum course reached
touching a part
Error 24, 25, 26, 27, 28, 29, 30 :
Z sensor Error
An error happened while
driving Z sensor axis
Restart the controller
Contact After Sales Service.
Error 31 : Plate detection error
No plate detected on the plate
charger
Load the plate charger
Contact After Sales Service.
Error 32 : Stuck plate error
A plate is stuck in the plate
charger
Remove the stuck plate
Error 33 : Loading plate error
Loading of a plate is too long
Contact After Sales Service
Error 34 : Discharging plate
error
Discharging of a plate is too
long
Contact After Sales Service
Error 39, 40, 41, 42 : EEPROM
error
Contact After Sales Service
Error 43,44,45,46: USB key
error
The USB key in use is faulty
Try a different USB key
Restart the controller
Internal controller fault
Contact After Sales Service.
Error 47 : Internal error
Restart the controller
Contact After Sales Service
Error 48 : Demo error
The demonstration date is
passed
Contact the marketing
department
Error 49 : Window error
A marking point is outside the
marking window
Check if there is a warning flag
showing a marking outside the
marking window in the marking
view. Reposition the text.
If still a problem, call After
Sales Service
Error 50 : Temperature error
The machine stayed too long in
easy shift mode, the motors
stayed too long under power
Stop the controller for about 10
minutes then start again
If still a problem, call After