Chapter 4 Software Index 
4-23 
 
Acc/ Dec time 1 
(00-09/0-10) 
Acc/ Dec time 2 
(10-05/10-06) 
JOG Acc/Dec time 
(00-13/00-14) 
Function 
 
preset value   
00-05/00-06 
determines the 
output frequency
00-05/00-06 
determines the   
output frequency 
Run at 00-12   
Jog frequency 
01-00~01-05=06/07  
Jog command 
Off Off  On 
01-00~01-05=08  
Toggle Acc/Dec time 
Off On  Off 
 
00-11 : Operation modes for external terminals     
0:Forward/stop-reverse/stop 
1:Run/stop-forward/reverse 
2:3-wire control mode -run/stop 
1.) When operation command 00-03/00-04 = 0 (external terminal), 00-11is valid. 
2.) When operation command 00-03/00-04 = 1 (external terminal control), the stop button for 
emergency is available. (Refer to04-02 for detail description). 
3.) That both forward and reverse commands are ON will be treated as STOP. 
 
 
 
 
 
 
 
 
 
3、00-11 = 2, Control mode is as below: 
Figure 4-7 Terminal Board Drive Operation Modes 
Figure 4-8 3-Wire start/stop wiring 
S1 (RUN) 
S2 (STOP) 
S3 (FWD/REV) 
COM (0V)