EasyManua.ls Logo

TECO N310 Series - Auto Run Function Group

TECO N310 Series
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Software Index
4-19
12-07 Parameter Lock
0: Enable all Functions
1: 03-01~03-16 cannot be changed
2: All Functions cannot be changed Except
03-01~ 03-16
3: Disable All Function
0
12-08 Parameter password 00000~65535 00000
12-09 Copy Unit Reserved
13-Auto Run function group
Function
Code No.
Description Range/Code
Factory
Setting
Remarks
13-00 Auto Run( sequencer) mode selection
0: Disabled.
1: Single cycle.
(Continues to run from the
Unfinished step if restarted).
2: Periodic cycle.
(Continues to run from the
unfinished step if restarted).
3: Single cycle, then holds thespeed Of
final step to run.
(Continues to run from the unfinished
step if restarted).
4: Single cycle.
( starts a new cycle if restarted).
5: Periodic cycle.
( starts a new cycle if restarted).
6: Single cycle, then hold the speed of
final step to run.
( starts a new cycle if restarted).
0
13-01 Auto _ Run Mode Frequency Command 1
13-02 Auto _ Run Mode Frequency Command 2
13-03 Auto _ Run Mode Frequency Command 3
13-04 Auto _ Run Mode Frequency Command 4
13-05 Auto _ Run Mode Frequency Command 5
13-06 Auto _ Run Mode Frequency Command 6
13-07 Auto _ Run Mode Frequency Command 7
13-08 Auto _ Run Mode Frequency Command 8
13-09 Auto _ Run Mode Frequency Command 9
13-10 Auto _ Run Mode Frequency Command 10
13-11 Auto _ Run Mode Frequency Command 11
13-12 Auto _ Run Mode Frequency Command 12
13-13 Auto _ Run Mode Frequency Command 13
13-14 Auto _ Run Mode Frequency Command 14
13-15 Auto _ Run Mode Frequency Command 15
0.00 ~ 400.00 (Hz)
0.00
13-16 Auto_ Run Mode Running Time Setting 0
13-17 Auto_ Run Mode Running Time Setting 1
13-18 Auto_ Run Mode Running Time Setting 2
13-19 Auto_ Run Mode Running Time Setting 3
13-20 Auto_ Run Mode Running Time Setting 4
13-21 Auto_ Run Mode Running Time Setting 5
13-22 Auto_ Run Mode Running Time Setting 6
13-23 Auto_ Run Mode Running Time Setting 7
0.0 ~ 3600.0 (second)
0.0

Table of Contents

Related product manuals