Chapter 4 Software Index
4-53
11-01: Custom Units (Line Speed) Value 0~65535
The max preset line value of 11-01 is equal to the rated frequency (06-04) of the motor. For instance,
given line speed 1800 is equal to display 900 when output is 30Hz while the operation frequency is
60Hz.
11-02: Custom Units (Line Speed) Display Mode
0: Drive Output Frequency is Displayed
1: Line Speed is Displayed in Integer (xxxx)
2: Line Speed is Displayed with One Decimal Place (xxx.x)
3: Line Speed is Displayed with Two Decimal Places (xx.xx)
4: Line Speed is Displayed with Three Decimal Places (x.xxx)
When 11-02=1/2/3/4, line speed is displayed while the inverter is running or stopped.
11-03: Max PID Feedback Setting =0 ~ 999
11-04: Min PID Feedback Setting =0 ~ 999
Example: 11-03=100, 11-04=50, 11-00=10000, When the feedback changes from minimum to
maximum, the feedback is displayed from 50 to 100 on the panel.
11-05: PID Feedback Display Mode
=0 : Displayed in Integer (xxx)
=1 : Displayed with One Decimal Place (xx.x)
=2 : Displayed with Two Decimal Places (x.xx)
11-06: PID Feedback Display Unit Setting
=0 : xxx--
=1 : xxxpbpressure
=2 : xxxflflow
Group12- User parameter group
12-00: Drive Horsepower Code
12-00 Inverter Model 12-00 Inverter Model
20P5 20P5
4001
4001
2001
2001
4002
4002
2002
2002
4003
4003
2003
2003
4005
4005
4008
4008
4010
4010
N310-
4015
N310-
4015

Table of Contents