Chapter 4 Software Index
4-56
13-22 : Auto_ Run Mode Running Time Setting 6 ( 0-3600sec)
13-23: Auto_ Run Mode Running Time Setting 7 ( 0-3600sec)
13-24: Auto_ Run Mode Running Time Setting 8 ( 0-3600sec)
13-25: Auto_ Run Mode Running Time Setting 9 ( 0-3600sec)
13-26: Auto_ Run Mode Running Time Setting 10 ( 0-3600sec)
13-27: Auto_ Run Mode Running Time Setting 11 ( 0-3600sec)
13-28: Auto_ Run Mode Running Time Setting 12 ( 0-3600sec)
13-29: Auto_ Run Mode Running Time Setting 13 ( 0-3600sec)
13-30: Auto_ Run Mode Running Time Setting 14 ( 0-3600sec)
13-31: Auto_ Run Mode Running Time Setting 15 ( 0-3600sec)
13-32: Auto_ Run Mode Running Direction 0 (0: STOP 1:forward 2:reverse)
13-33: Auto_ Run Mode Running Direction 1 (0: STOP 1:forward 2:reverse)
13-34: Auto_ Run Mode Running Direction 2 (0: STOP 1:forward 2:reverse)
13-35: Auto_ Run Mode Running Direction 3 (0: STOP 1:forward 2:reverse)
13-36: Auto_ Run Mode Running Direction 4 (0: STOP 1:forward 2:reverse)
13-37: Auto_ Run Mode Running Direction 5 (0: STOP 1:forward 2:reverse)
13-38: Auto_ Run Mode Running Direction 6 (0: STOP 1:forward 2:reverse)
13-39: Auto_ Run Mode Running Direction 7 (0: STOP 1:forward 2:reverse)
13-40: Auto_ Run Mode Running Direction 8 (0: STOP 1:forward 2:reverse)
13-41: Auto_ Run Mode Running Direction 9 (0: STOP 1:forward 2:reverse)
13-42: Auto_ Run Mode Running Direction 10 (0: STOP 1:forward 2:reverse)
13-43: Auto_ Run Mode Running Direction 11 (0: STOP 1:forward 2:reverse)
13-44: Auto_ Run Mode Running Direction 12 (0: STOP 1:forward 2:reverse)
13-45: Auto_ Run Mode Running Direction 13 (0: STOP 1:forward 2:reverse)
13-46: Auto_ Run Mode Running Direction 14 (0: STOP 1:forward 2:reverse)
13-47: Auto_ Run Mode Running Direction 15 (0: STOP 1:forward 2:reverse)
Note:
In order to selection Auto Run function, you must set to 1-00~1-05=22, and then close the terminals.
1. Auto Run (sequencer) various modes cab is selected by parameter 13-00.
2. Auto Run (sequencer ) mode set up parameters are parameters (13-01~13-47).
3. Auto run mode (sequencer) operation as selected by parameter 13-00 can be set up as follows:-
a. Setting multi-step frequency commands, by using the available multi-step frequency
commands 1~15 as required can be set by parameters (13-01~13-15).
b. Setting multi-step run time ,by parameters (13-16~13-31) for each required step.
c. FWD/REV direction can be selected by setting of parameters (13-32~13-47).