EasyManua.ls Logo

Thermal Dynamics CUTMASTER 151 - APPENDIX 10: INTERFACE PCB SWITCH SETTINGS (Division Factors 30-33)

Thermal Dynamics CUTMASTER 151
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX A-10 Manual 0-4691
A
APPENDIX 10: INTERFACE PCB SWITCH SETTINGS
(Division Factors 30-33)
Switch 1Switch 2Switch 3Switch 4Switch 5Switch 6Switch 7Switch 8
Divide Factor
0101000130.01
1000010130.03
0101001030.15
1000011030.17
0101001130.29
1000011130.31
0101010030.44
1000100030.49
0101010130.59
1000100130.64
0101011030.73
1000101030.78
0101011130.87
1000101130.92
0101100031.05
1000110031.07
0101100131.20
1000110131.21
0101101031.33
1000111031.35
0101101131.48
1000111131.50
0101110031.63
0101110131.77
1001000031.86
0101111031.91
1001000132.00
0101111132.05
1001001032.14
1001001132.28
0110000032.43
1001010032.44
0110000132.57
1001010132.58
0110001032.71
1001011032.72
0110001132.85
1001011132.86
Automation Interface Switch Setting Chart,
Division Factors 30-33
0 = DOWN = OFF, 1 = UP = ON
0 = DOWN = OFF, 1 = UP = ON