Tests and Diagnostics    
3-158 [CONFIDENTIAL] TECRA A11/S11/P11/Satellite Pro S500 Series Maintenance Manual (960-784) 
Test data = CCAA5533H, 8000000H 
 
Step 2: Byte Enable Test 
Write the data byte by byte to the initial address of the data in 64KB units and the initial 
data + 4, then read double words of the written data and compare the result with the original 
data. 
 
Test data = CCAA5533H, 8000000H 
Step 3: Data Bus Test 
Write double words of the data to the initial address of the data in 64KB units and the initial 
address + 4, then read double words of the written data and compare the result with the 
original data 
 
Test data = 1H, 2H, 4H, 8H, 10H, …… 8000000H, 0 
 
Step 4: Constant Data Test 
Write double words of the data to the whole of the data in 64KB units, then read double 
words of the written data and compare the result with the original data. 
 
Test data = FFFFFFFFh, 00000000h, 80018001h 
 
Step 5: Address Pattern Test 
Write double words of the data to the address pattern data, read double words of the written 
data and compare the result with the original data 
 
Test data = 0000H, 0004H, 0008H, 000CH ….. 
.. 8000H, 8004H ….FFECH 
 
If a compare error occurs, the write data, read data and test address are displayed on the test 
screen. 
 
1-2) The test information (Test address) during a test is displayed by 4 KB. Test step number 
is also displayed. 
 
2) Protected Mode 
This subtest writes constant data and address data (from 1MB to maximum MB), and reads 
the new data and compares the result with the original data.