TSC AUTO ID Technology Co., Ltd. 147 Copyright 2013 All Rights Reserved.
SET FILTER ON/OFF
Description
This command is using to enable/disable commands PREINPUT and POSTINPUT.
Syntax
SET FILTER ON/OFF
Parameter
Description
ON
Enable PREINPUT and POSTINPUT
OFF
Disable PREINPUT and POSTINPUT
Note:
This command has been supported since V6.81 EZ and later firmware.
Example
Sample Code
DOWNLOAD "TEST.BAS"
PREINPUT "<="
POSTINPUT "=>"
SET FILTER ON
START:
INPUT "DATA",data1$
SIZE 4,0.25
GAP 0,0
DIRECTION 1
CLS
TEXT 10,10,"3",0,1,1,"DATA = "+data1$
PRINT 1
GOTO START
EOP
TEST
<=1234=><=5678=><=9012=>
Result
See also
PREINPUT, POSTINPUT, INPUT

Table of Contents

Other manuals for TSC TDP-247

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TDP-247 and is the answer not in the manual?

TSC TDP-247 Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Communication InterfaceUSB 2.0, RS-232
Power Supply100-240V AC, 50/60 Hz
Operating Temperature41°F - 104°F (5°C - 40°C)
Operating Humidity85% non-condensing
Max. Print Width4.09" (104 mm)
Label Width1.18" - 4.33" (30 mm - 110 mm)
Storage Temperature-40 ~ 60°C (-40 ~ 140°F)