TSC AUTO ID Technology Co., Ltd. 32 Copyright 2013 All Rights Reserved.
DELAY
Description
Let the printer wait specific period of time then go on next command.
Syntax
DELAY ms
Parameter
Description
ms
The specific period of time. Unit is millisecond. 1000 ms = 1 second.
Note:
This command has been supported since V6.34 EZ and later firmware.
Example
Sample Code
SIZE 4,0.7
GAP 0,0
DIRECTION 1
CLS
TEXT 10,10,"3",0,1,1,"The delay time between two labels is 3 seconds."
TEXT 10,60,"3",0,1,1,"Now second:"+@SECOND
PRINT 1
DELAY 3000
PRINT 1
Result

Table of Contents

Other manuals for TSC TDP-247

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TDP-247 and is the answer not in the manual?

TSC TDP-247 Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Communication InterfaceUSB 2.0, RS-232
Power Supply100-240V AC, 50/60 Hz
Operating Temperature41°F - 104°F (5°C - 40°C)
Operating Humidity85% non-condensing
Max. Print Width4.09" (104 mm)
Label Width1.18" - 4.33" (30 mm - 110 mm)
Storage Temperature-40 ~ 60°C (-40 ~ 140°F)