Example (Use CommTool to get sensor status via RS-232.)
Sample code
OUT GETSENSOR("GAP",0)
OUT GETSENSOR("GAP",1)
OUT GETSENSOR("GAP",2)
OUT GETSENSOR("GAP",3)
OUT GETSENSOR("GAP",4)
OUT GETSENSOR("GAP",5)
OUT GETSENSOR("GAP",6)
OUT GETSENSOR("GAP",7)
OUT GETSENSOR("GAP",8)
Result
*If the returned valued is changed in different sensor
intension, we can say the sensor is functional.
Sample code
OUT GETSENSOR("BLINE",0)
OUT GETSENSOR("BLINE",1)
OUT GETSENSOR("BLINE",2)
OUT GETSENSOR("BLINE",3)
Result
*If the returned valued is changed in different sensor
intension, we can say the sensor is functional.
Sample code
OUT GETSENSOR("RIBBON",0)
OUT GETSENSOR("RIBBON",1)
OUT GETSENSOR("RIBBON",2)
OUT GETSENSOR("RIBBON",3)
Result
*If the returned valued is changed in different sensor
intension, we can say the sensor is functional.
Sample code
OUT GETSENSOR("PEEL")
Result
*0: Paper is not on the sensor. 1: Paper is on the sensor.

Table of Contents

Other manuals for TSC TDP-247

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TDP-247 and is the answer not in the manual?

TSC TDP-247 Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Communication InterfaceUSB 2.0, RS-232
Power Supply100-240V AC, 50/60 Hz
Operating Temperature41°F - 104°F (5°C - 40°C)
Operating Humidity85% non-condensing
Max. Print Width4.09" (104 mm)
Label Width1.18" - 4.33" (30 mm - 110 mm)
Storage Temperature-40 ~ 60°C (-40 ~ 140°F)

Related product manuals