Operation and Maintenance
Manual
Electronic Laboratory Autoclaves
Models 5050, 5075 EL-MD/EL-D
EL-MD: standard autoclave (manual door)
EL-D: standard autoclave (automatic door)
C: optional system for fast cooling
PV: optional vacuum pump
BH: optional bio hazard filtration
F: optional fan for super-fast cooling
Cat. No. MAN205-0469000EN Rev. L
Tuttnauer Europe B.V.,
Hoeksteen 11 4815 PR P.O. Box 7191 4800 GD Breda,
The Netherlands Tel: 31 (0) 765423510, Fax: 31 (0) 765423540
DOMINIQUE DUTSCHER SAS

Table of Contents

Other manuals for Tuttnauer 5050

Questions and Answers

  • D
    Dr. Brittney Webb MDSep 18, 2025
    What to do if Tuttnauer 5050 Laboratory Equipment safety valve does not release pressure?
    • H
      Heather RamosSep 22, 2025
      If the safety valve on your Tuttnauer Laboratory Equipment does not release pressure during a blow-off test: * If circulation is blocked, remove the obstruction. * If the issue persists, replace the faulty valve.
  • B
    brendatorresAug 29, 2025
    What to do if my Tuttnauer 5050 says 'Door is open (During the cycle)'?
    • D
      Danielle SmithAug 29, 2025
      If your Tuttnauer Laboratory Equipment displays a 'Door is open (During the cycle)' message, it means the door is open during the cycle. Close the door to perform a new cycle.
  • J
    Juan BrewerAug 29, 2025
    What does 'Time Error' mean on my Tuttnauer Laboratory Equipment and how do I resolve it?
    • M
      Maxwell CoxAug 29, 2025
      If your Tuttnauer Laboratory Equipment displays a 'Time Error' message, it means the real-time clock is faulty and the main board needs to be replaced.
  • M
    Mark LopezSep 7, 2025
    What to do if the chamber temperature is not in range in Tuttnauer 5050?
    • J
      jlawrenceSep 7, 2025
      If the chamber temperature of your Tuttnauer Laboratory Equipment is not within the expected range, wait until the chamber reaches the normal range temperature.
  • J
    Jenna HunterAug 28, 2025
    What does 'Compressed air supply error (C - cooling) only' mean on my Tuttnauer 5050 and how do I fix it?
    • T
      Taylor MartinezAug 28, 2025
      If your Tuttnauer Laboratory Equipment displays a 'Compressed air supply error (C - cooling) only' message, it indicates a malfunction in the compressed air supply. This can be due to the compressed air valve not opening because of a faulty connection or a faulty I.O. board, or the compressed air valve itself might be faulty. Check and fix the compressed air supply. If the problem persists, fix the connection, replace the faulty I.O. board, or replace the faulty valve.
  • B
    belljosephSep 14, 2025
    What does 'High Pressure (Exhaust)' indicate on my Tuttnauer Steriliser?
    • R
      Robert SmithSep 15, 2025
      If the Tuttnauer Steriliser displays 'High Pressure (Exhaust)', it means the system cannot reach preset pressure within 10 minutes from the beginning of the exhaust stage. You should perform a new cycle.
  • F
    Frank DawsonSep 9, 2025
    What to do if the 'Door is open' during the cycle on Tuttnauer Laboratory Equipment?
    • D
      deatonSep 9, 2025
      If your Tuttnauer Laboratory Equipment indicates that the 'Door is open' during the cycle, close the door to perform a new cycle.
  • T
    Travis WoodsSep 23, 2025
    Why Tuttnauer Laboratory Equipment printer feeds paper continuously?
    • V
      Valerie MortonSep 23, 2025
      If the printer feeds paper continuously when the Tuttnauer Laboratory Equipment is switched on, make sure the ‘feed button’ on the printer is not stuck.
  • D
    doughertyduaneSep 18, 2025
    What to do if Tuttnauer Laboratory Equipment shows low temperature I N I M?
    • D
      Dan SchultzSep 18, 2025
      If your Tuttnauer Laboratory Equipment displays a low temperature (I N I M) error, try the following: * Perform a new cycle, ensuring you do not overload the chamber. * Replace the door gasket. * Recalibrate the temperature and pressure sensors. * Check and fix any loose connections. * If the problem continues, replace any faulty temperature or pressure sensors, the SSR, or the Analog board.
  • M
    Margaret SmithAug 27, 2025
    What does 'High Pressure (Exhaust)' mean on my Tuttnauer 5050 Laboratory Equipment and how do I fix it?
    • J
      Jessica OliverAug 28, 2025
      If your Tuttnauer Laboratory Equipment displays a 'High Pressure (Exhaust)' message, it means the system couldn't reach the preset pressure within 10 minutes from the beginning of the exhaust stage. This can be due to the exhaust valve not opening because of a faulty connection or a faulty I.O. board, or the exhaust valve itself might be faulty. First, perform a new cycle. If the problem persists, fix the connection, replace the faulty I.O. board, or replace the faulty valve.

Summary

General Autoclave Information

Introduction to Autoclave Models

Overview of the laboratory sterilizer, its models, and features.

Incoming Inspection Procedures

Procedures for unpacking and inspecting the autoclave upon receipt.

Product Warranty Details

Details of the product warranty, coverage, and exclusions.

Warranty Registration and Service

Information on warranty registration and technical service contact.

Safety Instructions for Autoclave Operation

Technical Data and Specifications

Standards and Compliance

Lists relevant directives and standards the autoclave complies with.

Water and Utilities Specifications

Details water quality requirements and system utilities.

Electrical and Performance Data

Covers electrical configurations, operating conditions, and performance.

Physical and Environmental Data

Includes construction materials, emissions, and dimensions.

Model Specifications and Stickers

Provides detailed model specifications and sticker descriptions.

Autoclave Component Views

Diagrams showing the front and rear views of the autoclave.

Control Panel Interface

Control Panel Overview and Components

Diagram of the control panel and its numbered components.

Keypad Functions and Navigation

Explains the functions of the UP, DOWN, and START/STOP keys.

Displayed Messages and Symbols

Lists and explains operational and error messages and symbols.

Printer Integration Details

Describes the optional printer and its role in the system.

Sterilization Programs Overview

Program 1: Glass Sterilization

Details the Glass sterilization program parameters and sequence.

Program 2: Plastic Sterilization

Details the Plastic sterilization program parameters and sequence.

Program 3: Liquid A Sterilization

Details the Liquid A sterilization program, cautions, and sequence.

Program 4: Liquid B - Waste Sterilization

Details the Liquid B – Waste sterilization program, cautions, and sequence.

Program 5: Liquid A - Cooling

Details the Liquid A – Cooling program parameters and sequence.

Program 6: Liquid B - Waste Cooling

Details the Liquid B – Waste Cooling program parameters and sequence.

Program 7: Bio Hazard 1

Details the Bio Hazard 1 program for bio-hazard models.

Program 8: Bio Hazard 2

Details the Bio Hazard 2 program for bio-hazard models.

Program 9: Bio Hazard Liquids

Details the Bio Hazard Liquids program for bio-hazard models.

Program 10: Vacuum Test

Details the Vacuum Test program for PV models.

Program 11: Warm-Up

Details the Warm-Up program for pre-warming the chamber.

Program 12: Isothermal

Details the Isothermal program for liquids, agar, pasteurization.

Program 13: Air Mixture

Details the Air Mixture program for liquids in soft packages.

Program 14: Glass Test

Details the Glass Test program for checking bottle durability.

Program 15: Durham

Details the Durham program for liquids.

Autoclave Screen Displays

Successful Cycle Screens

Illustrates screens shown after a successful sterilization cycle.

Aborted Cycle Screens

Shows screens for cycles aborted after sterilization.

General Cycle Failure Screens

Illustrates screens indicating a general cycle failure.

Parameter and System Management

Menu Navigation and Parameter Adjustment

Instructions for browsing menus and changing parameters.

Quick Options and System Settings

Accessing quick options, setting date/time, and system parameters.

Cycle Parameter Configuration

Details on managing cycle parameters like Dry Time.

Printer Operations

Printer Output and Handling

Information on printer output content and paper handling.

Paper Treatment and Powering Off

Guidelines for treating thermal papers and powering off the printer.

Sterilization Preparation Guide

Instrument and Liquid Preparation

Guidelines for preparing instruments, tubing, and liquids.

Water Reservoir Filling Instructions

Instructions for filling the autoclave's water reservoir.

Operating the Autoclave

Powering On and Door Operations

Steps for turning on the autoclave and opening/closing doors.

Cycle Execution and Unloading

How to start, run, and unload the autoclave cycle.

Scheduled Cycle Start Function

Instructions for setting a future start time for the sterilization cycle.

Service and Maintenance Procedures

Preventive and Scheduled Tasks

Covers daily, weekly, periodic maintenance and tests.

Reservoir and Strainer Maintenance

Instructions for draining the reservoir and cleaning the strainer.

Safety Valve and Moving Procedures

Guidance on checking safety valves and moving the autoclave.

Troubleshooting Common Issues

Display, Printer, and Sensor Errors

Addresses issues with display, printer, sensors, and range errors.

Cycle, Pressure, and Time Errors

Covers system, cycle, pressure, and time-related errors.

Operational and Maintenance Faults

Addresses errors related to jacket temp, maintenance, water, vacuum, and cycle counts.

Baskets and Containers

Spare Parts List

Accessories List

Tuttnauer 5050 Specifications

General IconGeneral
BrandTuttnauer
Model5050
CategoryLaboratory Equipment
LanguageEnglish