EasyManua.ls Logo

Tuttnauer 5050 - User Manual

Tuttnauer 5050
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operation and Maintenance
Manual
Electronic Laboratory Autoclaves
Models 5050, 5075 EL-MD/EL-D
EL-MD: standard autoclave (manual door)
EL-D: standard autoclave (automatic door)
C: optional system for fast cooling
PV: optional vacuum pump
BH: optional bio hazard filtration
F: optional fan for super-fast cooling
Cat. No. MAN205-0469000EN Rev. L
Tuttnauer Europe B.V.,
Hoeksteen 11 4815 PR P.O. Box 7191 4800 GD Breda,
The Netherlands Tel: 31 (0) 765423510, Fax: 31 (0) 765423540
DOMINIQUE DUTSCHER SAS

Table of Contents

Other manuals for Tuttnauer 5050

Questions and Answers

  • J
    Jeffrey HowellSep 12, 2025
    Why is the safety relief valve on my Tuttnauer 5050 Laboratory Equipment constantly leaking?
    • E
      Eric CampbellSep 12, 2025
      If the safety relief valve on your Tuttnauer Laboratory Equipment leaks constantly, the valve is likely faulty and needs replacement. Additionally, check the water quality.
  • H
    hicksbrettSep 9, 2025
    What to do if cycle is 'Canceled By User' on Tuttnauer Laboratory Equipment?
    • D
      deborahwardSep 9, 2025
      If your Tuttnauer Laboratory Equipment displays 'cycle failed – canceled by user' or 'cycle end – canceled by user', wait until the message is displayed. Then, perform a new cycle.
  • P
    Patricia GarciaSep 23, 2025
    What to do if the printer does not print on Tuttnauer 5050?
    • C
      christophergonzalezSep 23, 2025
      If the Tuttnauer Laboratory Equipment printer does not print, first ensure that the paper is inserted in the printer. Then, switch off the machine and switch it back on while pressing the feed button on the printer. If the printer prints a test printout, the printer is O.K. and there is a problem with the electronics. Contact your dealer to solve the problem. If the printer does not print the test printout, there is a problem with the printer. Contact your dealer to solve the problem.
  • B
    brendatorresAug 29, 2025
    What to do if my Tuttnauer 5050 says 'Door is open (During the cycle)'?
    • D
      Danielle SmithAug 29, 2025
      If your Tuttnauer Laboratory Equipment displays a 'Door is open (During the cycle)' message, it means the door is open during the cycle. Close the door to perform a new cycle.
  • J
    Juan BrewerAug 29, 2025
    What does 'Time Error' mean on my Tuttnauer Laboratory Equipment and how do I resolve it?
    • M
      Maxwell CoxAug 29, 2025
      If your Tuttnauer Laboratory Equipment displays a 'Time Error' message, it means the real-time clock is faulty and the main board needs to be replaced.
  • J
    Janet MosleyAug 28, 2025
    How to fix 'RTC Error - Please Set Current Date and Time' on my Tuttnauer 5050?
    • D
      David LeeAug 29, 2025
      If your Tuttnauer Laboratory Equipment displays an 'RTC Error - Please Set Current Date and Time' message, it means you need to set the date and time. Set the current date and time. If the problem persists, the main board may need replacement.
  • J
    Jenna HunterAug 28, 2025
    What does 'Compressed air supply error (C - cooling) only' mean on my Tuttnauer 5050 and how do I fix it?
    • T
      Taylor MartinezAug 28, 2025
      If your Tuttnauer Laboratory Equipment displays a 'Compressed air supply error (C - cooling) only' message, it indicates a malfunction in the compressed air supply. This can be due to the compressed air valve not opening because of a faulty connection or a faulty I.O. board, or the compressed air valve itself might be faulty. Check and fix the compressed air supply. If the problem persists, fix the connection, replace the faulty I.O. board, or replace the faulty valve.
  • I
    ian99Sep 9, 2025
    What does 'High Pressure (Dry)' mean on Tuttnauer Laboratory Equipment and how do I resolve it?
    • T
      trobinsonSep 9, 2025
      If your Tuttnauer Laboratory Equipment displays 'High Pressure (Dry)', it means the pressure in the chamber exceeds atmospheric pressure by more than 10kPa at the beginning of the dry stage. To resolve this, perform a new cycle.
  • R
    Roger LinSep 12, 2025
    Why does the safety relief valve on my Tuttnauer Laboratory Equipment open at a pressure higher than specified?
    • S
      Sarah ThomasSep 12, 2025
      If the safety relief valve on your Tuttnauer Laboratory Equipment opens at a pressure higher (more than 10%) than specified, the relief valve is likely faulty and needs replacement.
  • Y
    ycarterSep 15, 2025
    Why is my Tuttnauer Steriliser leaking at the door?
    • G
      Gina CobbSep 15, 2025
      If the Tuttnauer Steriliser is leaking at the door, it could be due to a dirty or damaged door gasket. Clean the door gasket. Also, clean the surface against the door. If the issue persists, call for service.

Summary

General Autoclave Information

Introduction to Autoclave Models

Overview of the laboratory sterilizer, its models, and features.

Incoming Inspection Procedures

Procedures for unpacking and inspecting the autoclave upon receipt.

Product Warranty Details

Details of the product warranty, coverage, and exclusions.

Warranty Registration and Service

Information on warranty registration and technical service contact.

Safety Instructions for Autoclave Operation

Technical Data and Specifications

Standards and Compliance

Lists relevant directives and standards the autoclave complies with.

Water and Utilities Specifications

Details water quality requirements and system utilities.

Electrical and Performance Data

Covers electrical configurations, operating conditions, and performance.

Physical and Environmental Data

Includes construction materials, emissions, and dimensions.

Model Specifications and Stickers

Provides detailed model specifications and sticker descriptions.

Autoclave Component Views

Diagrams showing the front and rear views of the autoclave.

Control Panel Interface

Control Panel Overview and Components

Diagram of the control panel and its numbered components.

Keypad Functions and Navigation

Explains the functions of the UP, DOWN, and START/STOP keys.

Displayed Messages and Symbols

Lists and explains operational and error messages and symbols.

Printer Integration Details

Describes the optional printer and its role in the system.

Sterilization Programs Overview

Program 1: Glass Sterilization

Details the Glass sterilization program parameters and sequence.

Program 2: Plastic Sterilization

Details the Plastic sterilization program parameters and sequence.

Program 3: Liquid A Sterilization

Details the Liquid A sterilization program, cautions, and sequence.

Program 4: Liquid B - Waste Sterilization

Details the Liquid B – Waste sterilization program, cautions, and sequence.

Program 5: Liquid A - Cooling

Details the Liquid A – Cooling program parameters and sequence.

Program 6: Liquid B - Waste Cooling

Details the Liquid B – Waste Cooling program parameters and sequence.

Program 7: Bio Hazard 1

Details the Bio Hazard 1 program for bio-hazard models.

Program 8: Bio Hazard 2

Details the Bio Hazard 2 program for bio-hazard models.

Program 9: Bio Hazard Liquids

Details the Bio Hazard Liquids program for bio-hazard models.

Program 10: Vacuum Test

Details the Vacuum Test program for PV models.

Program 11: Warm-Up

Details the Warm-Up program for pre-warming the chamber.

Program 12: Isothermal

Details the Isothermal program for liquids, agar, pasteurization.

Program 13: Air Mixture

Details the Air Mixture program for liquids in soft packages.

Program 14: Glass Test

Details the Glass Test program for checking bottle durability.

Program 15: Durham

Details the Durham program for liquids.

Autoclave Screen Displays

Successful Cycle Screens

Illustrates screens shown after a successful sterilization cycle.

Aborted Cycle Screens

Shows screens for cycles aborted after sterilization.

General Cycle Failure Screens

Illustrates screens indicating a general cycle failure.

Parameter and System Management

Menu Navigation and Parameter Adjustment

Instructions for browsing menus and changing parameters.

Quick Options and System Settings

Accessing quick options, setting date/time, and system parameters.

Cycle Parameter Configuration

Details on managing cycle parameters like Dry Time.

Printer Operations

Printer Output and Handling

Information on printer output content and paper handling.

Paper Treatment and Powering Off

Guidelines for treating thermal papers and powering off the printer.

Sterilization Preparation Guide

Instrument and Liquid Preparation

Guidelines for preparing instruments, tubing, and liquids.

Water Reservoir Filling Instructions

Instructions for filling the autoclave's water reservoir.

Operating the Autoclave

Powering On and Door Operations

Steps for turning on the autoclave and opening/closing doors.

Cycle Execution and Unloading

How to start, run, and unload the autoclave cycle.

Scheduled Cycle Start Function

Instructions for setting a future start time for the sterilization cycle.

Service and Maintenance Procedures

Preventive and Scheduled Tasks

Covers daily, weekly, periodic maintenance and tests.

Reservoir and Strainer Maintenance

Instructions for draining the reservoir and cleaning the strainer.

Safety Valve and Moving Procedures

Guidance on checking safety valves and moving the autoclave.

Troubleshooting Common Issues

Display, Printer, and Sensor Errors

Addresses issues with display, printer, sensors, and range errors.

Cycle, Pressure, and Time Errors

Covers system, cycle, pressure, and time-related errors.

Operational and Maintenance Faults

Addresses errors related to jacket temp, maintenance, water, vacuum, and cycle counts.

Baskets and Containers

Spare Parts List

Accessories List

Tuttnauer 5050 Specifications

General IconGeneral
BrandTuttnauer
Model5050
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals