EasyManua.ls Logo

Utax CD 1020 - Page 92

Utax CD 1020
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-4-44
2AV/X
Description
Maintenance
item No.
1-4
U344 Setting preheat/energy saver mode
Description
Changes the control for preheat/energy saver mode.
Purpose
According to user request, selects which has priority, the recovery time from preheat or energy saver.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select control mode using the cursor up/down keys.
Without decreasing the fixing control tempera-
ture, the display on the operation panel is
turned off.
The fixing control temperature is set at
70°C/158°F. The copier is forcibly stabilized
30 s after exiting preheat/energy saver mode.
The fixing control temperature is set at
130°C/266°F.
Display
INSTANT READY
ENERGY STAR
TIME SERVE
Control in preheat mode
Initial setting: ENERGY STAR
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U345 Setting the value for maintenance due indication
Description
Sets when to display a message notifying that the time for maintenance is about to be reached, by setting
the number of copies that can be made before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance cycle and that of the maintenance
count reaches the set value, the message is displayed.
Purpose
To change the time to display the maintenance due indication.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the setting using the numeric or cursor left/right keys.
0 to 9999
Description
Display period for the next maintenance
(remaining count before the end of the maintenance cycle)
Setting range
Initial settin
g
: 0
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.

Table of Contents

Related product manuals