94 bright blue Installation Manual
Highlights
▪ Supports various read head technologies; Proximity, (Wiegand Format) and Magnetic Stripe
▪ Standard 26-bit
▪ Vanderbilt 34-bit
▪ Xceed-ID XF1050 Reader
▪ HID Corporate 1000 35-Bit (not evaluated by UL)
▪ HID Corporate 1000 48-Bit (not evaluated by UL)
▪ HID/ProxIF 37-Bit
▪ XceedID 40-Bit
▪ Vanderbilt 35-bit (including EV1)
▪ MiFare 32-Bit Serial Number
▪ Communicates via network protocol at 10Base-T
▪ Powered locally by a UL294 Listed Power-Limited, Power Supply capable of 4 hours’ standby power.
▪ OPTIONAL - can be powered directly from bright blue (see Cable Requirement Chart for details).
Standard Features
▪ Supports one read-head credential
▪ Communicates with bright blue via network protocol at 10/100 Base-T
▪ Connection for one multi-color LED for access granted or access denied indication
▪ Includes 4 input contacts for devices such as exit request (REX), door position switch (DOD), etc.
Specifications
▪ Board Dimensions: 151mm H x 201mm W x 53mm D
▪ Enclosure Dimensions: 8-1/4” H x 7-1/2” W x 3-1/2” D
▪ Power requirements: 9.5 VDC to 29.5 VDC
▪ Power consumption: 600 mA @ 12 VDC
▪ Ambient temperature: -40º to 55º C
VBB-NRI G2 Enclosure
VBB-NRI G2 Enclosure - An enclosure with a hinged door is included for each VBB-NRI G2.
Features
▪ Metal enclosure with hinged door
▪ Enclosure Dimensions: 8.25” x 7.5” x 3.5”