â–ª Locked - The relay will be deactivated when communication is lost. In most installations this will mean
that the door will become secured.
â–ª Power On - This section is used to define the behaviour of Relay 1 while bright blue is reloading the
VBB-NRI after a power loss. In the case of a power failure Relay 1 will become deactivated. When power
and communication are returned, bright blue will need to reload the VBB-NRI. During this time the Power
On option determines what state Relay 1 will be in. Once the VBB-NRI has been fully restored it will resume
its Normal Operation state.
â–ª Unlocked - The relay will be activated when the VBB-NRI receives power and is being reloaded. In
most installations, this will mean that the door will become unsecured.
â–ª Locked - The relay will be deactivated when the VBB-NRI receives power and is being reloaded. In
most installations, this will mean that the door will become secured.
VBB-NRI Pin Layout