Zone Type
Processing
Category
Description
LOCK ELEMENT Intruder If using a Lock Element (bolt) with a Blockschloss, this zone type signals
the position of the lock element to the panel (locked or unlocked). This bolt
locks the door in the set state. This signal is checked during setting process.
If the ‘locked‘information is not received, the setting will fail.
GLASSBREAK Intruder Zone is connected to an RI S 10 D-RS-LED glassbreak interface in
combination with GB2001 glassbreak detectors.
l This zone type is available on controllers and expanders.
It is not available as wireless or as a door zone type if the DC2 is
configured as a door.
l The zone type reports in the same way as an alarm zone over SIA and
contact ID.
l The rights to restore/inhibit/isolate glassbreak are the same as the alarm
zone type
l Power up condition — As the power is supplied by the panel any state
changes within the first 10 seconds are ignored in order to allow the
device to settle.
l Reset condition — Signals are ignored from the glassbreak interface for
3 seconds after the device has been reset.
l Exiting engineer mode — The glassbreak output may be toggled when
exiting engineer mode, in which case the signals from this sensor will be
temporarily ignored for 3 seconds.
WATER This zone type follows the same behaviours as a Technical zone type.
HEAT This zone type follows the same behaviours as a Technical zone type.
FRIDGE/FREEZER This zone type follows the same behaviours as a Technical zone type.
GAS This zone type follows the same behaviours as a Technical zone type.
SPRINKLER This zone type follows the same behaviours as a Technical zone type.
CO This zone type follows the same behaviours as a Technical zone type.
ENTRY/EXIT 2 This zone type follows the same behaviours as an Entry/Exit zone type with
a separate Entry timer. This is so that there can be two entry timers to a
building from different points.
* A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Appendix
© Vanderbilt 2018 383 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals