To add other languages to the panel, see Upgrading Languages on page340. To add other
languages to a keypad, see the documentation for that keypad. Installation guides are available
at http://www.spcsupportinfo.com/connectspcdata/userdata.
8. Enter the DATE and TIME.
The system scans the X-BUS for modems.
9. Enable SPC CONNECT to allow a panel to communicate with https://www.spcconnect.com
once the panel IP address is configured.
10. Enable DHCP to automatically assign an available network IP address to the panel. If you've
enabled SPC CONNECT and DHCP, an SPC CONNECT ATS is now added to the panel to
complete the connection to https://www.spcconnect.com
11. For DHCP enabled panels, the automatically assigned IP address displays in the IP ADDRESS
menu. If DHCP is not enabled, the default IP address displays. Choose SELECT to continue. In
Engineer Programming mode, under COMMUNICATIONS, you must manually enter the static
IP address for the panel.
12. Choose the X-BUS addressing mode:
- MANUAL: is recommended for most installation types, especially when doing a
preconfiguration.
- AUTO: is recommended only for very small installations.
13. Choose the installation topology: LOOP (Ring) or SPUR (Chain).
The system scans for the quantity of keypads, expanders, door controllers and available zone
inputs.
14. Press NEXT to scan all X-BUS devices.
PROGRAMMING MODE will be displayed.
The Start-up setting is complete.
15. Check the alerts in the menu SYSTEM STATUS > ALERTS. Otherwise you will not be allowed
to exit the Engineer Mode.
16. Configure the system by keypad or web browser.
See also
Domestic, Commercial and Financial mode default settings on page366
14.4 Creating system users
By default the SPC system only allows engineer access on the system. The engineer must create
Users to allow on-site personnel to set, unset, and perform basic operations on the system as required.
Users are restricted to a set of panel operations by assigning them to specific User Profiles.
The system allows all user PINs within the allowed PIN range, that is, if a 4 digit PIN is used then all
user PINs between 0000 and 9999 would be permissible.
See Users on page135 or Users on page196.
The ability to grant manufacturer access to the system (for example, allow a firmware upgrade of
the panel) is configured as a user right for a user profile. If a user is going to be enabling firmware
upgrades, ensure that the user has the correct profile for this purpose.
See also
Engineer PINs on page106
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Starting the system
© Vanderbilt 2018 108 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals