1. To configure an Event Exception Definition, complete the fields described in the table below.
Identification
Name Enter the name of the Event Exception.
Event ID Event ID of the event on the system. This is display only.
Event
Description
Description of the event. This is display only.
Event Filter
Report Event Check to report the event. This overrides the reporting value set for the event
Filter Group. For example, if the Filter Group Intruder Alarms is set to report,
you can exclude the BA event or by disabling this setting.
Filter
Exception
Enable
Check to exclude a range of addresses, for example Zone IDs, from the
Report Event field setting.
if (0 ≤ Zone ID
≤ 9999)
then Report
Event/Don't
Report Event
Enter a range of addresses to exclude from the Report Event setting. For
example, if you choose to report the event type BA, you may choose not to
report Zone ID 1 - 9 for that event.
Alternatively, if you choose not to report the event type BA, you may choose
to report Zone ID 1- 9 for that event.
Event Format
SIA Event
Code
Default SIA event code that is transmitted to represent the event. This field is
display only.
Contact ID
Event
Code/Qualifier
Default Contact ID Event Code/Qualifier transmitted to represent the event.
This field is display only.
Remap
Exception
Enable
Check to remap the default SIA, CID code/Qualifier and Event Address to
customised values, for example, to remap Zone ID 1 - 9 to Zone ID 101 - 109.
When enabled, the fields below display.
if (0 ≤ Zone ID
≤ 9999)
Enter the range of addresses to remap for an event, for example, if you want
to remap Zone ID 1 - 9 to Zone ID 101 - 109, enter 1 and 9. The quantity of
addresses in the range must be equal to the quantity of addresses defined in
the field Remap Event Address below.
then Remap
SIA Event
Code to BA
Remap the default SIA code to a customised SIA code.
and Remap
Contact ID
Event
Code/Qualifier
to
Remap the default CID Event Code/Qualifier to a customised CID Event
Code/Qualifier.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 321 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals