4 Technical Data
This chapter covers:
4.1 SPC4000 31
4.2 SPC5000 33
4.3 SPC6000 37
4.4 SPCP355.300 40
4.1 SPC4000
Programmable areas 4
Max. number of user PINs 100
Remote controls Up to 32
PACE Devices 32
Wireless Panic Alarm Up to 128
Event memory 1000 intrusion events, 1000 access events
Number of on-board zones 8
Max. number of hardwired zones 32
Max. number of wireless zones 32 (take away wired zones)
Max. number of Intrunet wireless
detectors per wireless receiver
(recommended)
20
EOL resistor Dual 4k7 (default), other resistor combinations configurable
Number of on-board relays 1 strobe (30V DC/1A resistive switching current)
Number of on-board open coll. 2 internal/external bell, 3 freely programmable (each max. 400mA resistive
switching current, supplied via auxiliary output)
Firmware V3.x
Door capacity Max. 4 entry doors or 2 entry/exit doors
Number of card reader Max. 4
Radio module l SPC4221: integrated SiWay RF receiver (868MHz)
l SPC4320.220: Optional (SPCW111)
l SPC4320.320: Optional (SPCW110)
Verification 4 verification zones with max. 4 IP-cameras and 4 audio devices.
Video Up to 16 pre/16 post event images (by JPEG resolution 320 x 240, max. 1
frame/sec.)
© Vanderbilt 2018 31 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals