14.3 Configuring start-up settings
The following start-up settings can be changed at a later time when programming the system functionality.
If powering up the panel the version number of the SPC system will be displayed on the keypad.
Prerequisite
o
To initialize the start-up configuration press the reset button on the PCB for at least 6 seconds.
1. Press a key on the keypad.
- Press NEXT after each setting to move to the next setting.
2. Choose the LANGUAGE in which the configuration wizard will be displayed.
3. Choose the appropriate REGION.
- EUROPE, SWEDEN SWITZERLAND, BELGIUM SPAIN UK IRELAND ITALY, , , , CANADA,
USA
4. Choose a TYPE of installation:
- DOMESTIC: is appropriate for home use (houses and apartments).
- COMMERCIAL: provides additional zone types and commercial zone default descriptions for the
first 8 zones.
- FINANCIAL: is specific for banks and other financial institutions and includes features such as
auto-setting, time locks, interlock groups and a seismic zone type.
For more details of default zone descriptions see Domestic, Commercial and
Financial mode default settings on page366.
5. Choose the Security Grade of your installation.
6. LANGUAGE View the default languages available on the system. The following shows the default
languages available for each region:
- IRELAND/UK -English, French, German
- EUROPE/SWITZERLAND/SPAIN/FRANCE/GERMANY – English, French, German, Italian,
Spanish
- BELGIUM – English, Dutch, Flemish, French, German
- SWEDEN – English, Swedish, Danish, French, German
NOTICE: If the system is defaulted, and the REGION is changed on start up, only
the languages that are currently on the system for the previous REGION will be
available for the new REGION.
7. Select the languages you require for your installation. Selected languages are prefixed with an
asterisk (*). To remove, or select, a language, press hash (#) on the keypad.
The unselected languages are deleted from the system and will be unavailable if you default the
system.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Starting the system
© Vanderbilt 2018 107 A6V10276959-d