Time=backup time, in hours, depending upon security grade
Icont=quiescent current (in A) for the SPC controller
Ibell=quiescent current (in A) for the attached external and internal bells
Imax=the maximum current that can be drawn from the auxiliary power output
Amount of current from Aux output using a 7Ah battery (SPC422x/522x)
COMMS
NONE (mA) PSTN (mA) GSM (mA) PSTN+GSM (mA)
Standby time
12 h 356 331 226 201
30 h 58 33 N/A N/A
Amount of current from Aux output using a 17Ah battery (SPC523x)
COMMS
NONE (mA) PSTN (mA) GSM (mA) PSTN+GSM (mA)
Standby time
12 h 750 750 750 750
30 h 342 317 212 187
Amount of current from Aux output using a 7Ah battery (SPC432x/532x)
COMMS
NONE (mA) PSTN (mA) GSM (mA) PSTN+GSM (mA)
Standby time
12 h 326 301 196 171
30 h 28 N/A N/A N/A
Amount of current from Aux output using a 17Ah battery (SPC533x/633x)
COMMS
NONE (mA) PSTN (mA) GSM (mA) PSTN+GSM (mA)
Standby time
12 h 750 750 750 750
30 h 312 287 182 157
Amount of current from Aux output using a 24Ah battery (SPC535x/635x)
COMMS
NONE (mA) PSTN (mA) GSM (mA) PSTN+GSM (mA)
Standby time
12 h 1650 1625 1610 1585
24 h 650 625 610 585
30 h 450 425 410 385
60 h 50 25 10 N/A
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Appendix
© Vanderbilt 2018 365 A6V10276959-d
11.2018