The SPCN110 PSTN module and SPCN320 GSM/GPRS module are tested with EN50131
approved Grade 2 and Grade 3 panels and can be used with these approved panels.
3.3 Compliance with EN 50136-1:2012 and EN 50136-2:2014
SPC products listed have been tested according to EN 50136-1:2012 and EN 50136-2:2014.
3.4 Compliance with INCERT Approvals
Software Requirements
Selecting Belgium (*) under Region implements local or national requirements which supercede
EN50131 requirements.
Selecting Grade 2 or Grade 3 selects EN50131 compliance plus any additional INCERT requirements:
l Only an engineer can restore a tamper. For INCERT, this applies across all grades.
This is normally only a requirement for Grade III En50131.
l A tamper on an Inhibited/Isolated zone must be sent to an ARC and displayed to the user.
For INCERT, tampers are processed for isolated zones. On all other standard variations,
tampers are ignored on isolated zones.
l User PIN codes must be defined with more than 4 digits.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Directives and standards
© Vanderbilt 2018 22 A6V10276959-d