Acronym EN50136-1 Description FlexC Example
SPT Supervised Premises Transceiver
ATE at the supervised premises including the interface to the AS
and the interface to one or more transmission networks and
being part of one or more ATPs.
Integrated onto SPC Panel using
Ethernet, GPRS, PPP over
PSTN.
FlexC also uses the following acronyms.
Acronym Description
ASP Analogue Security Protocols
The analogue security protocols traditionally used for alarm transmission over the telephone network, for
example, SIA, Contact ID.
23.23 FlexC Commands
The following table lists the commands that you can enable for a command profile. The command profile
you assign to an ATS defines how you can control a panel from SPC Com XT.
Command Filter Commands
System Commands Get Panel Summary
Set the System Time and Date
Grant Engineer Access
Grant Manufacturing Access
Intruder Commands Get the Area Status
Get the Change Mode Status of an Area
Change the mode (Set/Unset) of an Area
Get Status of Panel Alerts
Perform actions on Alerts
Silence Bells
Get Zone Status
Control a Zone
Get the System Log
Get the Log for a Zone
Get the Wireless Log
Output Commands Get Mapping Gate Status
Control Mapping Gates
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Appendix
© Vanderbilt 2018 394 A6V10276959-d
11.2018