Vertiv™ NetSure™ Control Unit (NCU) User Manual
253
<ocrdat>
This is the date when the triggering event occurred (i.e., the threshold was crossed). The format for <ocrdat> is MOY-
DOM. MOY ranges from 1 to 12 and DOM ranges from 1 to 31. A <null> value for this parameter defaults to the date in
the message header.
<ocrtm>
This is the time when the event occurred. The format for <ocrtm> is HOD-MOH-SOM. HOD ranges from 0 to 23. MOH
and SOM range from 0 to 59. A <null> value for this parameter defaults to the time in the message header.
NOTE!
The following two parameters do not apply to this application. A <null> value is inserted for them.
<locn> - location of alarm condition
<dirn> - direction of alarm condition
<monval>
This is the measured value of the monitored value associated with the alarm condition. A <null> value is inserted if
there is no measured value associated with this trouble.
<thlev>
This is the value of the threshold level if the <condtype> is a threshold violation. A <null> value means there is no
threshold level associated with the alarm condition.
<tmper>
This is the accumulation time period for PM parameters. In this application it represents the length of time the alarm
condition has been active. The format for this parameter is “VAL-UN”, where valid values for VAL (value) and UN
(units) are given below.
VAL UNIT
1 DAY (days) - used if alarm is active longer than 24 hours.
1 to 24 HR (hours)
1 to 1440 MIN (minutes) - used if alarm is active less than 24 hours.
<conddescr>
This parameter is a text message which provides a detailed description of the alarm, event, or condition. It is an ASCII
string enclosed within a pair of escaped quotes (\”). It may also be used to describe any action to be taken as a result
of the condition. For this application, values are derived from the condition description configuration parameter of the
controller configuration with which the alarm condition is associated. If the parameter has not been configured, a <null>
is inserted for this parameter.
Unimplemented Parameters
NOTE!
The following parameters are either not implemented or do not apply to this application. A <null> value is inserted for
them.
<aiddet> - supplementary equipment identification
<obsdbhvr> - observed behavior that resulted in reported trouble