Manual VIPA CPU 21x Chapter 5 Deployment CPU 21x-2BT02 with H1 / TCP/IP
HB103E - Rev. 05/45 5-17
Like described before the CPU 21x-2BT02 is delivered with a predefined
Ethernet address.
You will find this predefined address on the label at the side of the module.
When using the module for the first time this default address is changed
into an individual IP address following this rules:
00 20 D5 80 2D 7D
Ethernet address
hex
->
dec
213.128.45.125
IP-address
VIPA-specifi
Choose „IP protocol“ in the Protocol-window and type the determined IP
address. Confirm your entry with [OK].
Now switch to the window network and click the according station. Use the
right mouse button and choose „Download“.
Your project will now be directly transferred into the RAM of the CP.
Since the data are stored unsecured in the RAM, you have to store these
durable in the Flash ROM using
. With each further flash command
the date will be replaced.