EasyManuals Logo

Wacker Neuson E3000 User Manual

Wacker Neuson E3000
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
wc_tx001951gb.fm
70
Operation E 3000
Continued from the previous page.
7. Lift and hold the HTF fill switch (b) in the ON position (I) and watch the HTF
reservoir sightglass (c)—release the HTF fill switch when the HTF level is seen
in the HTF reservoir sightglass.
NOTICE: Do not overfill the HTF reservoir. Doing so may damage the machine.
8. Press and release the “RESET” button (d) on the low-level shut-down device.
The following will occur:
The “POWER” (green) (f) and “LOW WATER” (red) (e) lights will blink for fif-
teen seconds while the low-level shut-down device performs a self-diagnos-
tic test.
After 15 seconds, the “LOW WATER” light will go out—the “POWER” light will
stay on.
The low HTF level indicator will go out.
Power will be returned to the pumps.
Power will be returned to the burner.
9. Move the right pump switch to the ON position (I) and continue to fill the HTF
reservoir until the HTF level is between the two marks on the HTF reservoir
sightglass.
NOTICE: Do not overfill the HTF reservoir. Doing so may damage the machine.
This procedure continues on the next page.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson E3000 and is the answer not in the manual?

Wacker Neuson E3000 Specifications

General IconGeneral
Electrical Requirements230 V, 50 Hz
Voltage230 V
Operating Voltage230 V
Heat Capacity3000 W
Fuel Consumption0.3 l/h
Tank Capacity12 l
Fuel Tank Capacity12 l
Heating Capacity3000 W
Fuel Consumption (l/h)0.3 l/h
Tank Capacity (l)12 l
Power Consumption3 kW