7. Lift and hold the HTF fill switch (b) in the ON position (I) and watch the HTF
reservoir sightglass (c)—release the HTF fill switch when the HTF level is seen
in the HTF reservoir sightglass.
NOTICE: Do not overfill the HTF reservoir. Doing so may damage the machine.
8. Press and release the “RESET” button (d) on the low-level shut-down device.
The following will occur:
The “POWER” (green) (f) and “LOW WATER” (red) (e) lights will blink for fif-
teen seconds while the low-level shut-down device performs a self-diagnos-
tic test.
After 15 seconds, the “LOW WATER” light will go out—the “POWER” light will
stay on.
The low HTF level indicator will go out.
Power will be returned to the pumps.
Power will be returned to the burner.
9. Move the right pump switch to the ON position (I) and continue to fill the HTF
reservoir until the HTF level is between the two marks on the HTF reservoir
sightglass.
NOTICE: Do not overfill the HTF reservoir. Doing so may damage the machine.