January 2016
2-58
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
08-500
Status Indicator RAPs
• Upper exit roll, PL 10.15 Item 23.
• Lower exit roll, PL 10.15 Item 14.
• Transport roll, PL 10.15 Item 22.
• Transport roll idlers, PL 10.15 Item 19.
12. Install new components as necessary:
• Fuser, PL 10.28 Item 1.
• Exit assembly, PL 10.15 Item 1.
13. Perform the OF5 Main PWB Check RAP.
4265 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the Main
PWB PJ location illustration.
NOTE: The side cover assembly interlock switch must be closed to supply +24V to the motors
and clutches.
Refer to Wiring Diagram 38 and Wiring Diagram 39. Perform the following:
1. Open the side cover assembly, PL 7.30 Item 1. Remove all jammed paper.
2. Check the paper path for damage or obstructions.
3. Remove the fuser, PL 10.10 Item 4. Check that the exit sensor actuator, PL 10.28 Item 12
moves freely and is not damaged. If necessary, install a new fuser, PL 10.28 Item 1.
4. Enter dC330 code 08-600. Check the exit sensor (Q08-600), PL 10.15 Item 2.
5. Check the wiring between the exit sensor and CN2 on the Main PWB. If necessary, install
a new exit sensor, PL 10.15 Item 2.
6. Enter dC330 code 10-400. Check that the fuser motor (MOT10-400), PL 10.20 Item 3,
runs and drives the fuser rolls and transport roll, PL 10.15 Item 22.
7. Check the wiring between the fuser motor and CN28 on the Main PWB. Install new com-
ponents as necessary, PL 10.15 and PL 10.28.
8. Enter dC330 code 04-200. Check that the exit motor (MOT04-200), PL 10.20 Item 2, runs
and drives the upper exit roll, PL 10.15 Item 23.
9. Check the wiring between the exit motor and CN28 on the Main PWB. Install new compo-
nents as necessary, PL 10.15 and PL 10.20.
10. If the fault occurs in duplex mode, perform the following:
•Enter dC330 code 08-870. Check that the duplex gate solenoid (SOL08-870), PL
10.15 Item 4 energises and lowers the duplex gate, PL 10.15 Item 15.
• Check the duplex gate for damage. If necessary, install a new duplex gate, PL 10.15
Item 15.
• Check the wiring between the duplex gate solenoid and CN2 on the Main PWB. If
necessary, install a new duplex gate solenoid, PL 10.15 Item 4.
11. Check that the following components are clean and rotate freely:
• Upper exit roll, PL 10.15 Item 23.
• Lower exit roll, PL 10.15 Item 14.
• Transport roll, PL 10.15 Item 22.
• Transport roll idlers, PL 10.15 Item 19.
12. Install new components as necessary:
• Fuser, PL 10.28 Item 1
.
• Exit assembly, PL 10.15 Item 1.
13. Perform the OF5 Main PWB Check RAP.