Alarm List
Alarm Number (4000 to 4999)
Alarm List-818
23 Incorrect designation of the
occupation control group for
welding path shift function.
Software operation error
occurred
(1)Reset the alarm, select [UTILITY]-[ARC SHIFT CANCEL], and then
try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
24 The inverse shift data for
welding path shift function
could not correctly be
calculated.
Software operation error
occurred
(1)Reset the alarm, select [UTILITY]-[ARC SHIFT CANCEL], and then
try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
25 The inverse shift data for
welding path shift function
could not correctly be added.
Software operation error
occurred
(1)Reset the alarm, select [UTILITY]-[ARC SHIFT CANCEL], and then
try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4598 PAINTOUT ERROR 1 The parameter setting for the
universal input group number
is incorrect.
Setting error (1)Check the following settings.
∙ Check the settings for the AxP011.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4599 SERVO COMMAND
ERROR
An attempt was made to issue
the command while the servo
control processing has not
completed.
Sub Code: Servo CPU bit
number
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4601 UNDEFINED GUN
COND FILE
Sub Code: Gun condition file
number
Setting error (1)Check the following settings.
∙ Complete the gun condition file setting.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4603 WIRE STICKING Sub Code: Welder number Setting error (1)Check the following settings.
∙ Remove the cause of wire stick.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy