EasyManua.ls Logo

YASKAWA DX200 - Page 1040

YASKAWA DX200
1166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm List
Alarm Number (4000 to 4999)
Alarm List-819
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4604 SPECIFIED ERR
(ABSO RECOVER
AXIS)
Setting error (1)Check the following settings.
Registration for the home position correction data.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4605 SETTOOL ERROR 1 The difference between the
current tool constant and a
new set value exceeded the
allowable range (parameter
set value).
Setting error (1)Check the following settings.
Correct the job so that the setting value of tag is allowable value.
Set the allowance amount of the tool data automatic setting function
maximum deviation (S3C1192) to large value.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4606 LACK OF GLOBAL
VARIABLE AREA
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4607 WRONG EXECUTION
OF MACRO INST
1 The execution macro job is
not set.
Setting error (1)Check the following settings.
Check the settings for execution macro job.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 The suspend macro job is not
set.
Setting error (1)Check the following settings.
Check the settings for suspend macro job.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy