Alarm List
Alarm Number (1000 to 1999)
Alarm List-360
2 The servo float function was
used for the axis for which the
axis endless function was
enabled.
The servo float function
cannot be used for the axis
which the axis endless
function was enabled.
Setting error Disable either the axis endless function or the servo float function of
corresponding axis.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 The encoders manufactured
by Tamagawa Seiki Co., Ltd.
was used for the axis for
which the axis endless
function was enabled.
The encoders manufactured
by Tamagawa Seiki Co., Ltd.
cannot be used for the axis
which the axis endless
function was enabled.
Setting error Disable the corresponding axis endless function.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4 The general servo function
was used for the axis for
which the axis endless
function was enabled.
The general servo function
cannot be used for the axis
which the axis endless
function was enabled.
Setting error Disable the corresponding axis endless function.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy