Alarm List
Alarm Number (4000 to 4999)
Alarm List-748
32775 The value for the unsigned 4-
byte data type variable
exceeded the maximum
value.
Setting error (1)Check the following settings.
Check the settings for variable, and then correct the job to fall within
the input range of the tag.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
32776 The value for the real-number
4-byte data type variable
exceeded the maximum
value.
Setting error (1)Check the following settings.
Check the settings for variable, and then correct the job to fall within
the input range of the tag.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
32782 The value for the character-
string type variable exceeded
the maximum value.
Setting error (1)Check the following settings.
Check the settings for variable, and then correct the job to fall within
the input range of the tag.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4447 DEFECTIVE TAUGHT
POINT (CIRC)
1 Starting point and destination
point are the same position.
Setting error Change the teaching points so that circular interpolation points do not
to same.
2 Any points of the circular
interpolation are the same
position.
Setting error Change the teaching points so that circular interpolation points do not
to same.
3 Any points of the circular
interpolation are the same
position as the center position.
Setting error Change the teaching points so that circular interpolation points do not
to same as the center point of circular path.
4 The three points taught for the
circular interpolation points
line in a straight line.
Setting error Change the teaching points so that circular interpolation points do not
line in a straight line.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy

Table of Contents