Setting Function Page
7 Accel/decel time selection 1 –
8 Baseblock command (N.O.) –
9 Baseblock command (N.C.) –
A Accel/decel ramp hold –
B Drive overheat alarm (oH2) –
C Analog terminal input selection –
F Through mode –
10 Up command –
11 Down command –
12 Forward Jog –
13 Reverse Jog –
14 Fault reset –
15 Fast Stop (N.O.) –
17 Fast Stop (N.C.) –
18 Timer function input –
19 PID disable –
1A Accel/decel time selection 2 –
1B Program lockout –
1E Reference sample hold –
20 to 2F Ext. pump fault –
30 PID integral reset –
31 PID integral hold –
32
Multi-Step Speed
Reference 4
–
34 PID soft starter cancel –
35 PID input level selection –
40
Forward run command
(2-Wire sequence)
–
41
Reverse run command
(2-Wire sequence)
–
42
Run command
(2-Wire sequence 2)
–
43
FWD/REV command
(2-Wire sequence 2)
–
47 Node setup –
51 Sequence Timer Disable –
52 Sequence Timer Cancel –
60 DC Injection Braking command –
61
External Speed Search
command 1
–
Setting Function Page
62
External Speed Search
command 2
–
63 Field weakening –
65 KEB Ride-Thru 1 (N.C.) –
66 KEB Ride-Thru 1 (N.O.) –
67 Communications test mode –
68 High Slip Braking (HSB) –
6A Drive enable –
73 Low City Press –
75 Up 2 command –
76 Down 2 command –
7A KEB Ride-Thru 2 (N.C.) –
7B KEB Ride-Thru 2 (N.O.) –
80 HAND Mode –
81 HAND Mode 2 –
82
<1>
PI Switch to Aux –
83 Alternate Multi-Setpoint (Q1-02) –
84 Alternate Multi-Setpoint (Q1-03) –
85 Alternate Multi-Setpoint (Q1-04) –
88 Volute-Thermostat Normally Open –
89 Volute-Thermostat Normally Closed –
8C Disable Pre-Charge –
8D Multi Setpoint 1 –
8E Multi Setpoint 2 –
8F Low Water Level –
90 High Water Level –
92 Reset Accum –
95 Remove Drive Disable –
A8 Secondary PI Disable (N.O.) –
A9 Secondary PI Disable (N.C.) –
AA Secondary PI Inverse Operation –
AB Secondary PI Integral Reset –
AC Secondary PI Integral Hold –
AD Select Secondary PI Parameters –
AF Emergency Override Forward Run –
B0 Emergency Override Reverse Run –
<1> Available in drive software versions PRG: 8552 and later.
Not available in drive models 4A0930 and 4A1200.
n
H2-01 to H2-03: Terminal M1-M2, M3-M4, and MD-ME-MF Function Selection
The drive has three multi-function output terminals. Table 4.22 lists the functions available for these terminals using H2-01,
H2-02, and H2-03.
No. Parameter Name Setting Range Default
H2-01 Terminal M1-M2 Function Selection (relay) 0 to 192 37: During Frequency Output
H2-02 Terminal M3-M4 Function Selection (relay) 0 to 192
42: Pressure Reached
<1>
H2-03 Terminal MD-ME-MF Function Selection (relay) 0 to 192 E: Fault
<1> Default is F: Through Mode in drive software versions PRG: 8551 and earlier.
4.7 Basic iQpump Setup and Application Preset Parameters