10.2 List of Parameters
10-19
Pn144
2
Model Following Control Bias
(Reverse Direction)
0 to 10000 0.1% 1000 Immediately Tuning
−
Pn145
2
Vibration Suppression 1
Frequency A
10 to 2500 0.1 Hz 500 Immediately Tuning
−
Pn146
2
Vibration Suppression 1
Frequency B
10 to 2500 0.1 Hz 700 Immediately Tuning
−
Pn147
2
Model Following Control Speed
Feedforward
Compensation
0 to 10000 0.1% 1000 Immediately Tuning
−
Pn148
2
2nd Model Following Control
Gain
10 to 20000 0.1/s 500 Immediately Tuning
−
Pn149
2
2nd Model Following Control
Gain Compensation
500 to 2000 0.1% 1000 Immediately Tuning
−
Pn14A
2
Vibration Suppression 2
Frequency
10 to 2000 0.1 Hz 800 Immediately Tuning
−
Pn14B
2
Vibration Suppression 2 Com-
pensation
10 to 1000 1% 100 Immediately Tuning
−
Pn14F
2 Control Related Switch 0000 to 0011
-
0011 After restart Tuning –
Pn160
2
Anti-Resonance Control Related
Switch
0000 to 0011
−
0010 Immediately Tuning
6.2.1,
6.4.1
,
6.3.1, 6.5.1
Pn161
2 Anti-Resonance Frequency 10 to 20000 0.1 Hz 1000 Immediately Tuning
−
Pn162
2
Anti-Resonance Gain
Compensation
1 to 1000 1% 100 Immediately Tuning
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled
Classifi-
cation
Reference
Section
Model Following Control Type Selection
Reference
Section
0 Model Following Control 1
6.2.1,
6.4.1,
6.3.1
1
Model Following Control 2
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Anti-Resonance Control Selection
0 Does not use anti-resonance control.
1 Uses anti-resonance control.
Anti-Resonance Control Adjustment Selection
0 Does not adjust anti-resonance control automatically using utility function.
1 Adjusts anti-resonance control automatically using utility function.
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.