EasyManua.ls Logo

YASKAWA JUSP-MD D01A Series - Page 343

YASKAWA JUSP-MD D01A Series
363 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Appendix
10.2.2 Parameters
10-24
Pn460
2 Notch Filter Adjustment Switch 0000 to 0101
0101 Immediately Tuning
6.2.1
6.2.1
6.3.1
Pn501
2 Zero Clamp Level 0 to 10000
1 min
-1
10 Immediately Setup 5.3.5
Pn502
2 Rotation Detection Level 1 to 10000
1 min
-1
20 Immediately Setup 5.10.3
Pn503
2
Speed Coincidence Signal Out-
put Width
0 to 100
1 min
-1
10 Immediately Setup 5.3.8
Pn506
2
Brake Reference
-
Servo OFF
Delay Time
0 to 50 10 ms 0 Immediately Setup 5.2.4
Pn507
2
Brake Reference Output Speed
Level
0 to 10000
1 min
-1
100 Immediately Setup 5.2.4
Pn508
2
Waiting Time for Brake
Signal When Motor Running
10 to 100 10 ms 50 Immediately Setup 5.2.4
Pn509
2
Instantaneous Power Cut Hold
time
20 to 50000 1 ms 20 Immediately Setup 5.2.6
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled
Classifi-
cation
Reference
Section
Notch Filter Adjustment Selection 1
0 Does not adjust 1st step notch filter automatically using utility function.
1 Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0 Does not adjust 2nd step notch filter automatically using utility function.
1 Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents

Related product manuals