10.2 List of Parameters
10-27
10
Appendix
Pn50C
2 Input Signal Selection 3 0000 to FFFF
8888 After restart Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled
Classifi-
cation
Reference
Section
/SPD-D Signal Mapping
(Refer to 5.6 Internal Set Speed Control.)
Reference
Section
0 Active when CN1-40 input signal is ON (closed).
5.6.1
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 Reserved (Do not use.)
8 Not active (fixed).
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
/SPD-A Signal Mapping
(Refer to 5.6 Internal Set Speed Control.)
Reference
Section
0 to F
Same as /SPD-D Signal Mapping.
5.6.1
/SPD-B Signal Mapping
(Refer to 5.6 Internal Set Speed Control.)
Reference
Section
0 to F
Same as /SPD-D Signal Mapping.
5.6.1
/C-SEL Signal Mapping (Control method change when ON (closed))
Reference
Section
0 to F
Same as /SPD-D Signal Mapping.
5.7.1
4th 3rd 2nd 1st
digit digit digit digit
n.
