10.1 List of Parameters
10-13
Pn310
2 Vibration Detection Switch 0000 to 0002 − 0000 Immediately Setup −
Pn311 2
Vibration Detection
Sensibility
50 to 500 1% 100 Immediately Tuning
6.16
Pn312 2 Vibration Detection Level 0 to 5000
1 min
-1
50 Immediately Tuning
Pn324 2
Moment of Inertia Calculating
Start Level
0 to 20000 1% 300 Immediately Setup 5.3.2
Pn401 2
Torque Reference Filter Time
Constant
0 to 65535 0.01 ms 100 Immediately Tuning 5.9.3
Pn402 2 Forward Torque Limit 0 to 800
1%
*2
800 Immediately Setup
4.6.1
Pn403 2 Reverse Torque Limit 0 to 800
1%
*2
800 Immediately Setup
Pn404 2 Forward External Torque Limit 0 to 800
1%
*2
100 Immediately Setup
4.6.2
Pn405 2 Reverse External Torque Limit 0 to 800
1%
*2
100 Immediately Setup
Pn406 2 Emergency Stop Torque 0 to 800
1%
*2
800 Immediately Setup 4.3.2
Pn407 2
Speed Limit during Torque
Control
0 to 10000
1 min
-1
10000 Immediately Setup 4.8.8
∗2. Percentage (%) of rated motor torque.
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Vibration Detection Selection
Reference
Section
0 Does not detect vibration.
6.16
1 Outputs warning (A.911) when vibration is detected.
2 Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.