3 Wiring and Connection
3.1.3 Using the SERVOPACK with Single-phase, 200 V Power Input
3-12
(3) Main Circuit Wire for SERVOPACKs
The official model number is SGDV-120A11A008000.
(4) Wiring Example with Single-phase 200-V Power Supply Input
SERVOPACK with Single-phase, 200-V Power Supply
Applicable SERVOPACK Model: SGDV-R70A, -R90A, -1R6A, -2R8A, -5R5A, and -120A11A008000.
Termin a l
Symbols
Name
Model SGDV-A (Unit: mm
2
)
R70 R90 1R6 2R8 5R5 120*
L1, L2
Main circuit power input termi-
nals
HIV1.25 HIV2.0 HIV3.5
L1C, L2C Control power input terminals HIV1.25
U, V, W
Servomotor connection termi-
nals
HIV1.25 HIV2.0
B1/ , B2
External regenerative resistor
connection terminals
HIV1.25
Ground terminal HIV2.0 or larger
1PL
1KM
2KM
1SA
2SA
L1
0 V
1Ry
1D
2KM
L3
B2
B3
L2
U
V
W
M
1QF
R
T
1FLT
+24 V
ENC
1
2
L1C
1KM
L2C
3SA
B1/
+
3
4
CN1
1KM
1Ry
1KM
ALM
ALM
1Ry
1PL
1SA
2SA
3SA
1D:
: Indicator lamp
: Surge absorber
: Surge absorber
: Surge absorber
Flywheel diode
1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay
SERVOPACK
SGDV-A
(For servo
alarm display)
supply ON
Servo power
supply OFF
Servo power