Digital Operator/Monitor Functions
5-61
5
Displaying User-set Parameters Only
The A2 parameters (user-set parameters) and A1-01 (parameter access level) can be used to establish a param-
eter set that contains only the most important parameters.
Set the number of the parameter to refer in A2-01 to A2-32, and then set A1-01 to 1. Using the advanced pro-
gramming mode A1-01 to A1-03 and the parameters set in A2-01 to A2-32 can be read and modified.
Related Parameters
Parameter
No.
Name
Factory
Setting
Change
during
Operation
Control Methods
V/f
Open
Loop
Vector
Closed
Loop
Vector
A2-01
to
A2-32
User setting parameters - No A A A