* The wire thickness is set for copper wires at 75°C.
L7C4030
R/L1, S/L2, T/L3, , 1, 3, U/T1, V/T2,
W/T3, R1/L11, S1/L21, T1/L31, NO, PO
M6 4.0 to 5.0
22
(4)
22
(4)
Power cables,
e.g., 600 V vinyl
power cables
M8 9.0 to 10.0
22 to 38
(4 to 2)
22
(4)
L7C4037
R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/
T3, R1/L11, S1/L21, T1/L31, NO
M8 9.0 to 10.0
22 to 60
(4 to 1/0)
38
(2)
3, PO
M6 4.0 to 5.0
8 to 22
(8 to 4)
-
M8 9.0 to 10.0
22 to 38
(4 to 2)
22
(4)
L7C4045
R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/
T3, R1/L11, S1/L21, T1/L31, NO
M8 9.0 to 10.0
38 to 60
(2 to 1/0)
38
(2)
3, PO
M6 4.0 to 5.0
8 to 22
(8 to 4)
-
M8 9.0 to 10.0
22 to 38
(4 to 2)
22
(4)
L7C4055
R/L1, S/L2, T/L3, , 1, U/T1, V/T2,
W/T3, R1/L11, S1/L21, T1/L31, NO
M8 9.0 to 10.0
50 to 60
(1 to 1/0)
50
(1)
3, PO
M6 4.0 to 5.0
8 to 22
(8 to 4)
-
M8 9.0 to 10.0
22 to 38
(4 to 2)
22
(4)
Inverter
Model
CIMR-
Terminal Symbol
Termi-
nal
Screws
Tightening
Tor q u e
(N•m)
Possible
Wire Sizes
mm
2
(AWG)
Recom-
mended
Wire Size
mm
2
(AWG)
Wire Type
http://nicontrols.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed L7 and is the answer not in the manual?

YASKAWA Varispeed L7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed L7
CategoryInverter
LanguageEnglish

Related product manuals