Display
F6-01
Operation
selection
after commu-
nications
error
Sets the stopping method for
communications errors.
0: Deceleration to stop using
the deceleration time in C1-
02
1: Coast to stop
2: Emergency stop using the
deceleration time in C1-09
3: Continue operation
0 to 3 1 No A A A 3A2H -
BUS Fault
Sel
F6-02
Input level of
external error
from Com-
munications
Option Card
0: Always detect
1: Detect during operation
0 or 1 0 No A A A 3A3H -
EF0 Fault
Detection
F6-03
Stopping
method for
external error
from Com-
munications
Option Card
0: Deceleration to stop using
the deceleration time in C1-
02
1: Coast to stop
2: Emergency stop using the
deceleration time in C1-09
3: Continue operation
0 to 3 1 No A A A 3A4H -
EF0 Fault
Action
F6-04
Trace sam-
pling from
Communica-
tions Option
Card
-
0 to
60000
0 No A A A 3A5H -
Trace Sam-
pling Time
F6-05
Current mon-
itor unit
selection
Sets the unit of current monitor
0: Ampere
1: 100%/8192
0 or 1 0 No A A A 3A6H -
Current Unit
Sel
F6-06
Torque refer-
ence/torque
limit selec-
tion from
communica-
tions option
card
0: Torque reference/torque
limit by communications
option disabled.
1: Torque reference/torque
limit by communications
option enabled.
0 or 1 0 No No No A 3A7H -
Torque Ref/
Lmt Sel