Names and Functions of Parts
Displaying the Measured/Computed Results
START STOP
REMOTE
CAL
SENSOR RATIO
MEASURING
RMS MEAN DC RMEAN
CURRENT RANGEVOLTAGE RANGE
MEASURING
RMS MEAN DC RMEAN
ALL
INPUT INFO.
LOWER ITEM LOWER FORM ALL
USER SET
DISPLAY
ITEM & ELEMENT
2
34
COMPEN
ELEMENT
ELEMENT
1
WIRING
MODE AUTO MODE
AUTO
EXT SENSOR
RESET SET
PAGE PAGE
NUMERIC
WAVE
OTHERS
ITEM
FORM
U / I / P
WP/q/
TIME
USER
ELEMENT
UPDATE
RATE
HOLD
SINGLE
INTEG
LOCAL
SHIFT
• MODE Key (See section 5.2)
Switches the voltage mode and current mode. The mode can be set to true rms value
(RMS), rectified mean value calibrated to the rms value (MEAN), simple average
(DC), or rectified mean value (RMEAN) for the voltage mode and current mode,
separately.
• NUMERIC Key (See section 3.15 and 5.1. For details on the harmonic
measurement (/G6 or /G5 option), see the
Expansion Function User’s Manual
IM760301-51E
.)
Displays the screen that shows the numeric data.
• Pressing the ITEM key (explained later) while showing the numeric data opens a
menu for changing the displayed items.
• Pressing the FORM key (explained later) while showing the numeric data opens a
menu for changing the number of displayed items. For harmonic measurement (/
G6 or /G5 option), a list showing the measured values for each harmonic order can
also be selected.
• WAVE Key (See section 3.15 and 6.1 to 6.8)
Displays the screen that shows the waveform.
• Pressing the ITEM key (explained later) while showing the waveform opens a
menu for selecting the displayed waveform or a menu for zooming the waveform.
• Pressing the FORM key (explained later) while showing the waveform opens a
menu for setting the time axis of the displayed waveform, the trigger for displaying
the waveform on screen, the number of divided waveform display windows, the
assignment of waveforms to the divided windows, etc.
• OTHERS Key (See section 3.15, 7.1 to 7.6, and 7.8. For details on bar graphs or
vector displays (option), see the
Expansion Function User’s Manual IM760301-
51E.
)
Displays a menu for selecting the screen that shows the trend, bar graph,*
1
vector,*
1
IEC harmonic measurement,*
2
waveform computation,*
2
FFT,*
2
voltage fluctuation
and flicker measurement,*
3
and cycle-by-cycle measurement.*
4
*1 Only on models with the /G6 or /G5 option.
*2 Only on models with the /G6 option.
*3 Only on models with the /FL option.
*4 Only on models with the /CC option.
1.2 Setup Menu Display Key and Execution Key

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA wt3000 and is the answer not in the manual?

YOKOGAWA wt3000 Specifications

General IconGeneral
Frequency RangeDC, 0.1 Hz to 1 MHz
Number of Input ElementsUp to 4 elements
Harmonic MeasurementUp to 500th order
InterfacesUSB, Ethernet, RS-232
Sampling Rate2 MS/s
Voltage Range1.5 V to 1000 V
Display8.4-inch LCD