Maintenance and Troubleshooting
179
4-Slot Charge Only Cradle
During 
communication, no 
data transmits, or 
transmitted data was 
incomplete.
Device removed from 
cradle during 
communications.
Replace device in cradle and retransmit.
Incorrect cable 
configuration.
Ensure that the correct cable configuration.
Device has no active 
connection.
An icon is visible in the status bar if a connection is 
currently active.
Table 21    Troubleshooting the 1-Slot Charge Only Cradle (Continued)
Symptom Possible Cause Action
Table 22    Troubleshooting the 5-Slot Charge Only Cradle
Problem Cause Solution
Battery is not 
charging.
Device 
removed from 
the cradle too 
soon.
Replace the device in the cradle. The standard battery 
charges from fully depleted to 90% in approximately three 
hours. The extended battery charges from fully depleted to 
90% in approximately four hours.
Battery is faulty. Verify that other batteries charge properly. If so, replace the 
faulty battery.
Device is not 
inserted 
correctly in the 
cradle.
Remove the device and reinsert it correctly. Verify charging 
is active. Touch   > System > About phone > Status to 
view battery status.
Ambient 
temperature of 
the cradle is too 
warm.
Move the cradle to an area where the ambient temperature 
is between 5°C (41°F) and 40°C (104°F).