P1036102-007 ZXP Series 7 Card Printer Service Manual 113
Replacement Procedures for the Printer
Procedures: Print Engine
Test and Adjustment
Platen Drive Motor Belt Tension Adjustment
For this test, you will need the Gate 507C Sonic Tension Meter.
Step 1. Turn the Sonic Tension Meter power on (press the red Power button).
Step 2. Select measurement setting No02 (press the 2 button).
Step 3. Ensure the meter parameters (preset by Zebra Engineering) are set to:
M 001.1 g/m
W 006.0 mm/R
S 0029 mm
Step 4. Set the range to High (press and hold the Range button until the range
selections display, then use the UP and DOWN buttons to select the desired
range).
Step 5. Press the green Measure button. The green light below the number pad will
flash indicating that measurement is in progress.