Figure 47. Conversion Results
I/O Settings Section 3 Device Import Wizard
102 9ARD000014-600 A
Conversion results section lists warnings or minor errors which may have
occurred during file conversion/import. For instance, illegal characters
(characters that do not fall within the 0-127 ASCI range) are replaced with an
underscore, and the HWD file is created.
Click Vi
ew/Print HWD to view and print the generated HWD file.
18. Click Fi
nish to exit the Device Import Wizard. The *.hwd file is added in the
hardware library.
For details on re-import scenarios, refer to Re-import on page 168.
In case the configuration imported for EDS file is not correct, the hardware type
should not be deleted from the hardware library, after it has been created by
importing an EDS file in Control Builder.
Instead, to correct the configuration, re-import the EDS file in the same hardware
library, or create a new hardware library and import the EDS file under it.